=============================================================================== Tivoli Storage Manager Device Support README for AIX Version 4, Release 1, Mod 2, Level 0 Licensed Materials - Property of IBM 5698-TSM (C) Copyright IBM Corporation 1990, 2000. All rights reserved. US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp =============================================================================== This document includes updated information for the documentation provided with Tivoli Storage Manager for AIX Version 4.1.2.0 =============================================================================== New Device Support =============================================================================== For information on new devices being supported by the Tivoli Storage Manager server, please point your web browser to the following URL: http://www.tivoli.com/support/storage_mgr/devices_aix.html Highlight: New Drive Support ----------------- 1. IBM 7208 Mammoth-2 Drive New Library Support ------------------- 1. Exabyte 430 Library 2. HP SureStore 6/100, 6/120, 6/140 Libraries 3. IBM 7334-410 Library 4. Spectra Logic 12000 Library 5. Spectra Logic 64000 Library New Format Support ------------------ 1. M2 and M2C Formats for Mammoth-2 Drive ******************************************************************************* The following tables list the Formats and Capacities of new devices supported by the Tivoli Storage Manager server. ******************************************************************************* Tape Drives ----------- |========================================================================| | Device Name | Supported Formats | Estimated Capacity | |======================|============================|====================| | IBM 7208 Mammoth-2 | M2, M2C | 60 GB (see note 1) | |========================================================================| Note : 1. Approximately 120 GB wih Data Compression assuming a data compression ratio of 2:1. Tape Libraries -------------- |========================================================================================| | Device name | Supported Drives | # Drives | # Slots | Support Type | Capacity | |=====================|===================|==========|=========|==============|==========| | Exabyte 430 | 8MM Mammoth 2 | 1~4 | 30 | Base | 1.8 TB | | (see figure 1) | | | | | | | HP SureStore 6/100 | DLT 8000 | 1~6 | 100 | Advanced | 4.0 TB | | HP SureStore 6/120 | DLT 8000 | 1~6 | 120 | Advanced | 4.8 TB | | HP SureStore 6/140 | DLT 8000 | 1~6 | 140 | Advanced | 5.6 TB | | (see figure 2) | | | | | | | IBM 7334-410 | 8MM Mammoth 2 | 1~4 | 30 | Base | 1.8 TB | | (see figure 3) | | | | | | | Spectra Logic 12000 | AIT-2 | 2~8 | 120 | Base | 6.0 TB | | (see figure 4) | | | | | | | Spectra Logic 64000 | AIT-2 | 2~32 | 640 | Advanced | 32.0 TB | | (see figure 4) | | | | | | |========================================================================================| New Formats ----------- M2 and M2C Formats DEFine DEVclass devclassname DEVType=8MM FORMAT=M2 ..... M2C M2 Specifies that Tivoli Storage Manager writes data using the M2 recording format for 8mm tapes without compression. This format results in a tape capacity of 60GB when using 225m AME cartridges. M2C Specifies that Tivoli Storage Manager writes data using the M2C recording format for 8mm tapes with compression. This format results in a cartridge capacity of approximately 150GB when using 225m AME cartridges. ******************************************************************************* Element Addresses and Notes for Newly Supported Tape Libraries ******************************************************************************* NOTE: The following figures depict the storage element addresses of tape libraries for which support has been added in Tivoli Storage Manager version 4.1.2.0. These are used in conjunction with Tivoli Storage Manager Version 4.1 Administrator's Guide and Administrator's Reference. These diagrams can be added to their sections for recording the SCSI ID's and device names. Element addresses are used by Tivoli Storage Manager to address the tape drive device and the storage slots contained by a SCSI Library/Autochanger. The Tivoli Storage Manager command DEFINE DRIVE utilizes the element address of each drive in a multi-drive library. The Tivoli Storage Manager command CHECKIN LIBVOL uses the address of a storage slot for libraries that do not have Entry/Exit ports. With the exception of DUAL LUN (Logical Unit Numbers) devices, you will need separate SCSI ID for your autochanger and a SCSI ID for each drive in your library device. Configure the autochanger and each drive in the library separately using the procedure described in the 'Configuring a Tape Drive, or Autochanger' section of the Tivoli Storage Manager Administrator's Guide. NOTE: On some libraries, the element addresses of the cartridge slots will not directly correspond to the slot numbers (e.g. slot number 1 may be element address 2, etc.). This is important because Tivoli Storage Manager will always reference cartridge slots by element addresses, not slot numbers. __________________________________ Figure 1 __________________________________ Default Element Addresses for Exabyte 430 Library ------------------------------------------------------------------------------- Addresses Addresses of Addresses of Addresses of Model #s of Drives Storage slots Transport Entry/Exit Slots ----------- ---------- ------------- ------------ ---------------- Exabyte 430 82-85 1-30 86 81 Fixed Cartridge Slots Tape Drives ------------------------------- --------------------- | | | | | | | | | | | | | | | | |21|22|23|24|25|26|27|28|29|30| | 82 | 83 | 84 | 85 | | | | | | | | | | | | | | | | | ------------------------------- --------------------- ---- | | Robot |86| | | ---- Magazine 2 Magazine 1 E/E Port ------------------------------- ---------------------- ---- | | | | | | | | | | | | | | | | | | | | | | | | |20|19|18|17|16|15|14|13|12|11| |10|9|8|7|6|5|4|3|2|1| |81| | | | | | | | | | | | | | | | | | | | | | | | | ------------------------------- ---------------------- ---- Notes: ------ 1. Exabyte 430 library supports barcode. 2. Auto cleaning is supported. The Clean Slot option designates the right-most fixed cartridge slot for a cleaning cartridge. The address of the cleaning cartridge slot is 30. 3. Exabyte 430 can emulate Exabyte 210 and Exabyte 480. Tivoli Storage Manager does not support 210 and 480 emulation options. 4. Firmware levels used during our validation process Library : Exabyte 430 FW : 2.0 Drive : Mammoth2 FW : v02j Figure 1 -- Default Element Addresses for Exabyte 430 tape library ------------------------------------------------------------------------------- __________________________________ Figure 2 __________________________________ Default Element Addresses for the HP SureStore 6/100, 6/120, 6/140 Libraries ------------------------------------------------------------------------------- Addresses Addresses of Addresses of Addresses of Model #s of Drives Storage slots Transport Entry/Exit Slots -------------- ---------- ------------- ------------ ----------------- HP 7200 6/100 1 - 6 31 - 129 0 20 HP 7200 6/120 1 - 6 31 - 149 0 20 HP 7200 6/140 1 - 6 31 - 169 0 20 Transport Element: _______ | 0 | |_______| Storage Slots: _________ __________ 160 |___160___| |____161___| :_________: :__________: 151 |___151___| |____169___| |____170*__| 20 --> I/E port for HP 6/140 _________ __________ 140 |___140___| |____141___| :_________: :__________: 131 |___131___| |____149___| |____150*__| 20 --> I/E port for HP 6/120 _________ __________ |__120____| |___121____| :_________: :__________: |__111____| |___129____| |___130*___| 20 --> I/E port for HP 6/100 _________ __________ |__100____| |___101____| :_________: :__________: |___91____| |___109____| _________ __________ |___80____| |____81____| :_________: :__________: |___71____| |____90____| _________ __________ |___60____| |____61____| :_________: :__________: |___51____| |____70____| _________ __________ |___40____| |____41____| :_________: :__________: |___31____| |____50____| Drives: ___ ___ | | | | | 6 | | 5 | |___| |___| ___ ___ | | | | | 4 | | 3 | |___| |___| ___ ___ | | | | | 2 | | 1 | |___| |___| Notes: ------ 1. Tivoli Storage Manager supports barcode on HP SureStore 7200. 2. Firmware levels used during our validation process Library : HP C7200-8000 FW : 1130 Drive : QUANTUM DLT8000 FW : 0114 Figure 2 -- Default Element Addresses for the HP SureStore 6/100, 6/120, 6/140 ------------------------------------------------------------------------------- __________________________________ Figure 3 __________________________________ Default Element Addresses for IBM 7334-410 Library ------------------------------------------------------------------------------- Addresses Addresses of Addresses of Addresses of Model #s of Drives Storage slots Transport Entry/Exit Slots ----------- ---------- ------------- ------------ ---------------- IBM 7334-410 82-85 1-30 86 81 Fixed Cartridge Slots Tape Drives ------------------------------- --------------------- | | | | | | | | | | | | | | | | |21|22|23|24|25|26|27|28|29|30| | 82 | 83 | 84 | 85 | | | | | | | | | | | | | | | | | ------------------------------- --------------------- ---- | | Robot |86| | | ---- Magazine 2 Magazine 1 E/E Port ------------------------------- ---------------------- ---- | | | | | | | | | | | | | | | | | | | | | | | | |20|19|18|17|16|15|14|13|12|11| |10|9|8|7|6|5|4|3|2|1| |81| | | | | | | | | | | | | | | | | | | | | | | | | ------------------------------- ---------------------- ---- Notes: ------ 1. IBM 7334-410 Library supports barcode. 2. Auto cleaning is supported. The Clean Slot option designates the right-most fixed cartridge slot for a cleaning cartridge. The address of the cleaning cartridge slot is 30. 3. Tivoli Storage Manager does not support emulation options on IBM 7334-410. 4. Firmware levels used during our validation process Library : IBM 7334-410 FW : 2.2 Drive : IBM-60GB FW : 02pR Figure 3 -- Default Element Addresses for IBM 7334-410 Library ------------------------------------------------------------------------------- __________________________________ Figure 4 __________________________________ Default Element Addresses for the Spectra GATOR 12000/64000 libraries ------------------------------------------------------------------------------- Addresses Addresses of Addresses of Addresses of Model #s of Drives Storage slots Transport Entry/Exit Slots ----------- ---------- ------------- ------------ ---------------- 12000 646-653 1 - 120 678 0 64000 646-677 1 - 640 678 0 Spectra GATOR 12000 ------------------- Transport Element: ______ | 678 | |______| Storage Slots: Top View Element Address & Slots Slots & Element Address (Bottom to Top) (Bottom to Top) ___ ___ | | | | | | | | 61-75 | | | | 46-60 |___| |___| ___ ___ | | | | | | | | 76-90 | | | | 31-45 |___| |___| ___ ___ | | | | | | | | 91-105 | | | | 16-30 |___| |___| ___ ___ | | | | | | | | 106-120 | | | | 1-15 |___| |___| Drives: _________ |___653___| |___652___| |___...___| |___...___| |___647___| |___646___| I/E Port: Element Address Slots _________ 0 |_________| |_________| :_________: :_________: |_________| |_________| Notes: ------ 1. Barcodes supported. 2. The library does not allow software to move tapes from the Entry/Exit ports. Therefore, Tivoli Storage Manager can not move tapes from the Entry/Exit ports to the storage slots. Tapes must be inserted to the library manually. The Tivoli Storage Manager "label libvolume" and "checkin libvolume" commands with option search=bulk or search=no are not supported on this library. 3. If there is mixed media in the library, the library must be partitioned. See library installation manual for details. 4. Firmware levels used during our validation process Library: SPECTRA GATOR FW: 0000 Drives : SONY SDX-500C FW: 01c9 SONY SDX-500C FW: 01c7 Figure 4 -- Default Element Addresses for the Spectra GATOR libraries -------------------------------------------------------------------------------